EN
All split systems
Equipment Dehumidifiers Solutions Blog
ENRU

Product specifications

SPLTINVM-30

Split system — ECO COOL — split inverter

Download as PDF
The Welkin SPLTINVM-30 split-system indoor unit — ECO COOL — split inverter.
ModelSPLTINVM-30
SeriesECO COOL: split inverter
Capacity (ton)2.5
Indoor unit modelMSTAGF-27HRFN1-QC5W
Outdoor unit modelMOTD30-27HFN1-QC5W
QCC RegistrationRegistered
RegionUAE

Performance

Power supply220–240 V, 1 phase, 50 Hz
Cooling capacity, T1 (Btu/h)28500 (11200–32000)
Cooling power input, T1 (W)2385 (900–3200)
Rated cooling current, T1 (A)10.77 (4–14.5)
EER, T1 (Btu/Wh)11.95
Cooling capacity, T3 (Btu/h)25400
Cooling power input, T3 (W)2880
Rated cooling current, T3 (A)12.91
EER, T3 (Btu/Wh)8.819
Heating capacity (W)8000 (3370–8792)
Heating power input (W)2116 (850–2400)
Rated heating current (A)9.68 (3.8–10.6)
COP (W/W)3.78
Max. input consumption (W)4910
Max. current (A)22.5

Indoor unit

Indoor air flow, Turbo / Hi / Mi / Lo (m³/h)1700 / 1450 / 1150 / 990
Noise level, Turbo / Hi / Mi / Lo (dB(A))54 / 50 / 44.5 / 39
Fan motor modelZKFP-58-8-20L
Fan motor input (W)86,2
Fan motor output (W)58
Fan speed by setting, high → low (rpm)1120 / 984 / 848
Net dimensions (W × D × H, mm)1259 × 283 × 362
Packing dimensions (W × D × H, mm)1340 × 385 × 450
Net weight (kg)17.8
Gross weight (kg)23.2

Outdoor unit

Compressor modelATF235D22TMT
Compressor typeRotary
Compressor brandGMCC
Compressor capacity (Btu/h)24293
Compressor input (W)1950
Compressor rated current (A)8.85
Thermal protectorInternal
Compressor oil / charge (ml)RB75EA / 670
Fan motor modelZKFN-120-8-2
Fan motor input (W)150
Fan motor output (W)120
Fan speed by setting, high → low (rpm)850 / 650
Net dimensions (W × D × H, mm)946 × 410 × 810
Packing dimensions (W × D × H, mm)1090 × 500 × 885
Net weight (kg)60.4
Gross weight (kg)65.1
Noise level (dB(A))59
RefrigerantR410A
Refrigerant charge (g)2150
Design pressure (MPa)4.8 / 1.5

Piping and operating conditions

Refrigerant pipe, liquid side, Ø (mm)9.52 (3/8")
Refrigerant pipe, gas side, Ø (mm)15.9 (5/8")
Max. pipe length (m)50
Max. height difference (m)25
Connection wiring (mm²)4 × 1.5
Power cable / plug3 × 4.0 / no-plug
ThermostatRemote control
Operating temperature (°C)16–30
Indoor temperature range, cooling (°C)16–32
Outdoor temperature range, cooling (°C)0–52
Application area (m²)36–53

Product features

Turbo mode

Full fan and compressor for the first minutes — the room cools about 60% faster after the door has been open.

Golden Fin

Corrosion-resistant coating on the coil fins, rated for 50 years in the salt and dust of the Gulf.

3D air flow, 4-way swing

Louvres swing both up-down and left-right, so cooled air reaches the whole room instead of one line.

Super silent

Fan, louvres and casing designed for low noise — quiet enough for a bedroom on the low setting.

Hidden LED night display

The status display dims or hides at night, so nothing glows in a dark room.